HODI Electrical Power Management System

HODI Electrical Power Management System
Product Detailed
HODI Electrical Power Management System

HODI Electrical Power Management System

You can check the internal power grid at whenever or in wherever and be provided with the refinement of the power management tools;

the situation of using power of each workshop, each team, each production line and each piece of equipment is stuck out a mile;

Timely find out the electrical abnormalities, equipment failure and avoid accidents.

System Introduction

HODI electrical power management system is committed to helping enterprises to achieve the management of electric, find problems in the power network timely, guide enterprises to improve the methods of using electricity, reduce energy consumption, improve efficiency.

Based on the data collecting and real-time monitoring of the key point for the factory and enterprise, the system achieves statistics and analysis on time interval, branch, branch line, branch equipment electricity. The system also has the line loss analysis, three-phase equilibrium analysis, harmonic analysis, error alarm and other features. It is a useful tool to strengthen the management of electricity for the enterprise.

Graph

 System Function

(1) Daily electric meter data reading (multiple rate)

Combined total active powerCombined total reactive powerForward and reverse active powerFour quadrant reactive powerForward and reverse maximum power load demand and the happened time

 (2)Load profile data reading

Total active power and total reactive powerTotal and A, B, C phase active power  Total and A, B, C phase reactive power  Total and A, B, C phase active power factorThree phase voltage and current

(3)Real time monitoring

Frequency, voltage, current, phase angleActive power, reactive power, power factorUnbalanced currentThe effective value of voltage fundamental componentsThe effective value of current fundamental components

(4)Real time warning

Real time receive:over voltage, over current, overload, under-voltage, loss voltage, loss current, three-phase unbalanced, over frequency or low frequency, inverse phase sequence, uncommon current after power off and so on.  

 (5)data query

According to the time and equipment to query all kinds of electric energy data.

 (6)load profile data query

Query according to the time and present all kinds of overload curve data.

 (7)Power consumption statistic

According to the team, workshop, production line to statistics power consumption.Reports types have daily report, monthly report quarterly and annual reports and so on. User-defined the time of the report.

(8) Remote data query

Through Web browser, can remote all kinds of data and reports.

 Application Effect

Energy saving, increase efficient, reduce cost and promote the competition of company

Before

After

 Lack of energy management

Do not understand the details of electrical condition, unclear electric energy is mainly consumed in which place, cannot undertake effective management

Raise the way of energy management

The internal electricity details stick out a mile; know each workshop, each team, each production line and each piece of equipment, each time the conditions of power.

The energy wasting is serious.

Lack of energy management, the energy wasting is serious.

Prevent wasting

According to the system of data collection, through the corresponding set of index and measures of rewards and punishments, prevent to the waste of electric energy behavior, so that employees always pay attention to energy saving and consumption reducing.

The quality of energy is not so good.

Harmonic pollution is serious, resulting in the deterioration of the quality of power grid. Voltage, current unstable, three-phase unbalanced, line loss is too large will affect the quality of electric energy

Promote the quality of energy.

For enterprises to provide a scientific monitoring and diagnostic means, find the power problems, propose solutions, and help enterprises to upgrade the old way. Through transforming, power quality and utilization rate is improved, prolonged the service life of the device.

Danger is not been found.

With the load increasing, line loss increases, and does not regular maintenance. There are many safe hidden troubles.

Danger would be found in time.

Factory electricity monitoring system with real-time monitoring function, can quickly find the hidden safety problems of lines and equipment, avoid the occurrence of safety accidents.